General method of ultrasonic cleaning

- Sep 12, 2018-

1. Refer to the ultrasonic cleaning machine installation manual to connect the temperature control sensor signal line, ultrasonic drive line, heater control line and other lines between the electric control cabinet and the main unit of the cleaning machine, and connect the 380VAC power supply, install the upper water pipe of the cleaning machine, put Water pipe and overflow drain pipe.


2. Ultrasonic cleaning pool

Add an appropriate amount of clean water to the cleaning tank. The height of the liquid level shall be the same as the parts to be cleaned, and generally not more than three-quarters of the cleaning tank.


3. Ultrasonic cleaning and heating

Start the electronically controlled heating switch and point the white scale line on the water temperature adjustment knob to the appropriate temperature (should be about 60 °C). The maximum temperature of the cleaning solution should not exceed 70 °C during use.


4. Ultrasonic cleaning machine added to cleaning agent

When the water temperature rises to about 40 °C, add the component cleaning agent to the cleaning tank (at a ratio of 15% each time), and slowly stir the water to dissolve it completely (this can also activate the ultrasonic or open the bubbling device). Stirring).


5. Ultrasonic cleaning machine pretreatment

Before cleaning, it is advisable to use a bamboo knife to first remove the dirt on the surface of the parts (for example, there will be a lot of dust on the outer surface of the dust cover, and the parts of the cylinder block will accumulate a lot of thick and easy-to-remove sludge in the change of the outer casing curve). In order to extend the life of the cleaning fluid.